Prospective Multicenter Evaluation of a Novel Low-Axial-Force Colonic Stent for Malignant Colorectal Obstruction.

Self-expandable metal stents (SEMSs) are used as a bridge to surgery (BTS) or for palliation (PAL) in malignant colorectal obstruction, but high axial force may contribute to perforation. We prospectively evaluated the efficacy and safety of the low-axial-force Naturfit colonic stent in both settings.

This prospective multicenter single-arm study enrolled 208 patients at 11 Japanese institutions between 2019 and 2022 (BTS, n = 137; PAL, n = 71). The primary endpoint was clinical success of colorectal stenting; secondary endpoints included technical success, adverse events, surgical outcomes after BTS stenting, and 12-month palliative outcomes.

Technical success and clinical success of colorectal stenting were both 99.0%, with perforation in three patients (1.4%). In the BTS cohort, clinical success of BTS was 97.1%; no perforations occurred, and early and late adverse-event rates were 1.5% and 3.7%. All patients underwent elective surgery; colostomy and laparoscopic surgery rates were 4.4% and 87.6%. In the palliative cohort, clinical success of colorectal stenting was 98.6%, late adverse events occurred in 16.9%, and 12-month overall survival and stent patency were 46.6% and 67.6%.

Naturfit achieved high technical and clinical success of colorectal stenting with a low perforation rate. These findings support its feasibility for malignant colorectal obstruction in both BTS and palliative settings, although comparative studies are needed to determine relative advantages over other SEMSs.

University Hospital Medical Information Network Clinical Trial Registry: UMIN000035224.
Cancer
Care/Management

Authors

Otsuka Otsuka, Saito Saito, Fujimoto Fujimoto, Hanabata Hanabata, Takao Takao, Narita Narita, Kuwai Kuwai, Endo Endo, Omori Omori, Enomoto Enomoto, Yamamoto Yamamoto, Sasaki Sasaki, Saida Saida, Isayama Isayama
View on Pubmed
Share
Facebook
X (Twitter)
Bluesky
Linkedin
Copy to clipboard