Elevated Serum Growth Differentiation Factor 15 Levels Predict Poor Prognosis in Patients With Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation.
Despite transcatheter aortic valve implantation (TAVI) reducing cardiovascular events in elderly patients with aortic stenosis (AS), the mortality rate is still high. Growth differentiation factor (GDF) 15 is reportedly a useful prognostic marker for clinical outcomes in the field of cardiovascular diseases, but it is still unclear if elevated serum GDF15 levels predict poor prognosis in patients with severe AS who undergo TAVI.
We measured the pre- and postoperative serum concentrations of GDF15 in 148 patients. The primary and secondary endpoints were all-cause death and a composite event including cardiovascular death, heart failure rehospitalization, stroke, and adverse bleeding event, respectively. There were 30 all-cause deaths and 21 composite events during a median follow-up period of 1,023 days. Both pre- and postoperative serum GDF15 levels were significantly increased with advancing Society of Thoracic Surgeons Predicted Risk of Mortality score. Multivariate Cox proportional hazards analysis revealed that preoperative serum GDF15 level was independently associated with the primary and secondary endpoints, and the postoperative serum GDF15 level was independently associated with the primary endpoint after adjustment for confounding risk factors. Receiver operating characteristic curve analysis for the primary endpoint showed a comparable area under the curve for the pre- and postoperative serum GDF15 levels.
Both the pre- and postoperative GDF15 concentration could be a feasible marker for clinical outcomes in Japanese patients undergoing TAVI.
We measured the pre- and postoperative serum concentrations of GDF15 in 148 patients. The primary and secondary endpoints were all-cause death and a composite event including cardiovascular death, heart failure rehospitalization, stroke, and adverse bleeding event, respectively. There were 30 all-cause deaths and 21 composite events during a median follow-up period of 1,023 days. Both pre- and postoperative serum GDF15 levels were significantly increased with advancing Society of Thoracic Surgeons Predicted Risk of Mortality score. Multivariate Cox proportional hazards analysis revealed that preoperative serum GDF15 level was independently associated with the primary and secondary endpoints, and the postoperative serum GDF15 level was independently associated with the primary endpoint after adjustment for confounding risk factors. Receiver operating characteristic curve analysis for the primary endpoint showed a comparable area under the curve for the pre- and postoperative serum GDF15 levels.
Both the pre- and postoperative GDF15 concentration could be a feasible marker for clinical outcomes in Japanese patients undergoing TAVI.
Authors
Edamura Edamura, Tamura Tamura, Otaki Otaki, Iizuka Iizuka, Kobayashi Kobayashi, Sugai Sugai, Wanezaki Wanezaki, Nishiyama Nishiyama, Hashimoto Hashimoto, Kinoshita Kinoshita, Kato Kato, Arimoto Arimoto, Watanabe Watanabe, Watanabe Watanabe
View on Pubmed