Robustness of proliferation-based constrained spatiotemporal fractionation under setup and radiobiological uncertainties in liver radiotherapy.

Spatiotemporal fractionation redistributes dose between fractions and may reduce normal-tissue exposure. Its sensitivity to setup uncertainty and radiobiological assumptions requires evaluation before clinical use.

To evaluate proliferation-based constrained spatiotemporal fractionation (p-cSTF) under geometric and radiobiological perturbations in conventionally fractionated liver radiotherapy. The focus was normal-liver dose.

Thirty-five patients with hepatocellular carcinoma were included. Uniform fractionation, proliferation-based spatiotemporal fractionation (p-STF), and p-cSTF were evaluated over 25 fractions. The primary comparison matched nominal mean gross tumor volume (GTV) biologically effective dose (BED); a supplementary comparison matched nominal model-derived tumor control probability (TCP). Setup tests comprised 18 single-axis offsets (± 1, ± 2, and ± 3 mm) and 24 transverse voxel offsets, each held constant over treatment. Thirty scenarios varied biological-model parameters; precision checks used two 480-scenario sequences. Nominal dose grids were evaluated under perturbations without reoptimization. Endpoints included physical dose, BED, equivalent dose in 2 Gy fractions (EQD2), coverage, and response-model scores.

Under biological-parameter variation, normal-liver (liver excluding GTV) BED was 26.22 ± 7.00 Gy for p-cSTF, 28.18 ± 7.57 Gy for Uniform, and 28.05 ± 7.76 Gy for p-STF. Corresponding EQD2 values were 14.92 ± 3.96, 16.05 ± 4.29, and 15.96 ± 4.39 Gy. Values are cohort means and between-patient standard deviations of patient-specific scenario means. Normal-liver BED remained lower with p-cSTF after nominal TCP matching, although fixed transverse offsets produced lower GTV TCP than with Uniform. Expanded sampling retained the direction of the liver-dose difference; the original 30 scenarios did not meet the specified precision criteria for scenario variability.

P-cSTF retained a simulated normal-liver dose advantage under the tested perturbations, including after nominal TCP matching. This advantage must be considered alongside target-response trade-offs and uncertainty in scenario-variability estimates. Clinical toxicity and treatment deliverability were not evaluated.
Cancer
Access
Care/Management
Advocacy

Authors

Ma Ma, Zhang Zhang, Chen Chen, Men Men, Dai Dai
View on Pubmed
Share
Facebook
X (Twitter)
Bluesky
Linkedin
Copy to clipboard