Serum 25(OH)D, albumin-corrected calcium, and diabetic retinopathy in type 2 diabetes: distinct dose-response patterns in a cold-region cohort.
Calcium and vitamin D have both been associated with diabetic retinopathy (DR), but whether they exhibit similar or distinct dose-response relationships with DR remains unclear. This study investigated the associations of albumin-corrected calcium and serum 25-hydroxyvitamin D [25(OH)D] with DR in patients with type 2 diabetes from northern China.
A cross-sectional study including 976 patients with type 2 diabetes was conducted between 2019 and 2024. Multivariable logistic regression was used to evaluate the associations of albumin-corrected calcium and 25(OH)D with DR, with eGFR and HbA1c included as covariates. Restricted cubic spline(RCS) analyses were used to characterize dose-response relationships, and stratified and sensitivity analyses were performed by renal function.
Patients with DR had higher albumin-corrected calcium levels and lower 25(OH)D concentrations than those without DR. After adjustment for potential confounders, albumin-corrected calcium was positively associated with DR, whereas 25(OH)D was inversely associated with DR. RCS analyses revealed distinct dose-response patterns. Albumin-corrected calcium showed a significant nonlinear association with the presence of DR, with the odds increasing markedly above 2.110 mmol/L, whereas 25(OH)D demonstrated an approximately linear inverse association.
Albumin-corrected calcium and 25(OH)D were independently associated with DR in patients with type 2 diabetes. The distinct dose-response patterns observed for calcium and vitamin D suggest that they may have different roles in the metabolic processes associated with DR.
A cross-sectional study including 976 patients with type 2 diabetes was conducted between 2019 and 2024. Multivariable logistic regression was used to evaluate the associations of albumin-corrected calcium and 25(OH)D with DR, with eGFR and HbA1c included as covariates. Restricted cubic spline(RCS) analyses were used to characterize dose-response relationships, and stratified and sensitivity analyses were performed by renal function.
Patients with DR had higher albumin-corrected calcium levels and lower 25(OH)D concentrations than those without DR. After adjustment for potential confounders, albumin-corrected calcium was positively associated with DR, whereas 25(OH)D was inversely associated with DR. RCS analyses revealed distinct dose-response patterns. Albumin-corrected calcium showed a significant nonlinear association with the presence of DR, with the odds increasing markedly above 2.110 mmol/L, whereas 25(OH)D demonstrated an approximately linear inverse association.
Albumin-corrected calcium and 25(OH)D were independently associated with DR in patients with type 2 diabetes. The distinct dose-response patterns observed for calcium and vitamin D suggest that they may have different roles in the metabolic processes associated with DR.